Cabletron Systems EMM-E6 Washer User Manual


 
Network Requirements
EMM-E6 Installation Guide C-3
Temperature: Multi-pair PVC 24 AWG telephone cables typically
have an attenuation of approximately 8-10 dB/100 m at 20°C (68°F).
The attenuation of PVC insulated cable varies significantly with
temperature. At temperatures greater than 40°C (104°F), we strongly
recommend using plenum-rated cable to ensure attenuation remains
within specification.
C.1.2 Multimode Fiber Optic Network
When connecting a multimode fiber optic link segment to the EMM-E6
(using an EPIM-F1/F2), ensure the network meets the following
requirements:
Cable Type: Use the following multimode fiber optic media:
- 50/125 µm fiber optic cabling
- 62.5/125 µm fiber optic cabling
- 100/140 µm fiber optic cabling
Attenuation: You must test the fiber optic cable with a fiber optic
attenuation test set adjusted for an 850 nm wavelength. This test
verifies that the signal loss in a cable falls within the following
acceptable levels:
- 13.0 dB or less for a 50/125 µm fiber cable segment
- 16.0 dB or less for a 62.5/125 µm fiber cable segment
- 19.0 dB or less for a 100/140 µm fiber cable segment
Budget and Propagation Delay: When you determine the maximum
fiber optic cable length to incorporate fiber runs into your network, you
must calculate and consider the fiber optic budget (a total loss of
10.0 dB or less is permissible between stations) and total network
propagation delay.
To determine the fiber optic budget, combine the optical loss due to
the fiber optic cable, in-line splices, and fiber optic connectors.
Typical loss for a splice and connector (together) equals 1 dB or less.
ICH1Book Page 3 Tuesday, August 6, 1996 3:06 PM