Chapter 4: Troubleshooting
4-2 EMM-E6 Installation Guide
STBY Amber
Indicates packets
will not be
forwarded for one
of two reasons:
Either the Spanning
Tree Algorithm has
put the
corresponding
Bridge Port into a
standby mode due
to detecting a data
loop condition, or
the bridging
functionality for the
port has been
disabled through
management.
Check with your Network
Administrator to find out if
the EMM-E6 was placed
intentionally in standby
mode.
If a Data loop does exist,
reconfigure the network to
remove the data loop.
RCV Amber
LED flashes to
indicate that a
segment is
receiving a frame.
If none of the receive LEDs
is flashing, the EMM-E6 is
not receiving frames on any
of the segments.
Check that each module is
firmly installed in the MMAC.
Ensure that all connected
ports are enabled.
Table 4-1 LANVIEW LED Messages (Continued)
LED Color Description
Error Condition/
Recommended Action
ICH1Book Page 2 Tuesday, August 6, 1996 3:06 PM