EMM-E6 Installation Guide 4-1
CHAPTER 4
TROUBLESHOOTING
This chapter provides diagnostic and troubleshooting information.
4.1 USING LANVIEW LEDS
The EMM-E6 uses the Cabletron Systems built-in visual diagnostic and
status monitoring system called LANVIEW. With LANVIEW, you can
quickly scan the EMM-E6 LEDs to observe network status or diagnose
network problems.
NOTE
The STBY, RCV, XMT, and CLN LEDs are in a matrix, which
provides these indicators for four of the EMM-E6 Ethernet
channels. To read the LEDs, the vertical column indicates the
interface or channel the LED designates, while the horizontal
row denotes the condition or statistic being monitored.
Table 4-1 LANVIEW LED Messages
LED Color Description
Error Condition/
Recommended Action
CPU
Green
(Flashing)
Normal operation.
If the LED is not lit, the
EMM-E6 may not be
receiving power. See the
Troubleshooting Checklist.
Red CPU error condition.
Press the Reset switch on
the EMM-E6 front panel to
re-initialize the board. This
may clear the error. If the
board does not re-initialize, it
has probably failed. Call
Cabletron Systems Technical
Support.