American Dryer Corp. AD-464 Clothes Dryer User Manual


 
42 American Dryer Corp. 450260-1
Outputs: (Green)
1. FSS - Fire Suppression
2. PRG2 - Programmable Output #2
3. R_HEAT - Rear Heat
4. AUDIO ALERT - Horn On
5. FWD - Basket (Tumbler) Forward
6. AIR JET - Air Jet On
7. PRG3 - Programmable Output #3
8. PRG1 - Programmable Output #1
9. F_HEAT - Front Heat
10. FAN - Blower Fan On
11. REV - Basket (Tumbler) Reverse
12. EOC - End Of Cycle Light
13. OCL4 - Open Collector Output #4
14. OCL3 - Open Collector Output #3
15. OCL2 - Open Collector Output #2
16. OCL1 - Open Collector Output #1
17. OCL5 - Open Collector Output #5
18. OCL6 - Open Collector Output #6
19. OCL7 - Open Collector Output #7
20. OCL8 - Open Collector Output #8
Inputs:
1. RDWN  (RED LIGHT EMITTING DIODE [L.E.D.])
This L.E.D. will indicate the status of the rear tilt. If
the rear of the dryer is down, then the L.E.D. is ON.
2. FDWN  (RED L.E.D.)
This L.E.D. will indicate the status of the front tilt. If
the front of the dryer is down, then the L.E.D. is ON.
3. RDRC  (RED L.E.D.)
This L.E.D. will indicate the status of the rear doors.
If the doors are closed, then the L.E.D. is ON.
4. RDRO  (RED L.E.D.)
This L.E.D. will indicate the status of the rear doors.
If the doors are open, then the L.E.D. is ON.
5. FDRC  (RED L.E.D.)
This L.E.D. will indicate the status of the front doors.
If the doors are closed, then the L.E.D. is ON.
6. FDRO  (RED L.E.D.)
This L.E.D. will indicate the status of the front doors.
If the doors are open, then the L.E.D. is ON.
7. TBOL  (RED L.E.D.)
This L.E.D. will indicate the status of the basket
(tumbler) overload contact. If the contact is closed,
then the L.E.D. is ON. If it faults open, then the
L.E.D. is OFF.
8. FNOL  (RED L.E.D.)
This L.E.D. will indicate the status of the fan overload
contact. If the contact is closed, then the L.E.D. is
ON. If it faults open, then the L.E.D. is OFF.
9. FAN  (RED L.E.D.)
This L.E.D. will indicate the status of the blower fan.
If the fan is on, then the L.E.D. is ON.
10. RBHL  (RED L.E.D.)
This L.E.D. will indicate the status of the rear burner
high limit disk. If the disk is closed (temperature
below 330º F [165º C]), then the L.E.D. is ON.
11. R_SS  (RED L.E.D.)
This L.E.D. will indicate the status of the rear sail
switch. If the switch is closed, then the L.E.D. is ON.
12. FBHL  (RED L.E.D.)
This L.E.D. will indicate the status of the front burner
high limit disk. If the disk is closed (temperature
below 330º F [165º C]), then the L.E.D. is ON.
13. F_SS  (RED L.E.D.)
This L.E.D. will indicate the status of the front sail
switch. If the switch is closed, then the L.E.D. is ON.
14. EXHL  (RED L.E.D.)
This L.E.D. will indicate the status of the exhaust
high limit disk. If the disk is closed (temperature
below 225º F [107º C]), then the L.E.D. is ON.
15. DRY  (RED L.E.D.)
This L.E.D. will indicate the status of the
programmable logic controller (PLC). If the
mechanical functions of the dryer have been set to
the DRY position, the PLC will send a signal to the
Phase 7 board. This signal will indicate that all the
doors are closed and the dryer is level. When these
conditions are met, then the L.E.D. is ON.
16. LINT  (RED L.E.D.)
This L.E.D. will indicate the status of the lint drawer.
If the drawer is closed, then the L.E.D. is ON.
17. R_HE
Supply power for rear heat output.
18. F_HE
Supply power for front heat output.
19. 24VIN  (RED L.E.D.)
This L.E.D. will indicate the status of the control
voltage. If the power on button is pressed (green
button light is on), then the L.E.D. is ON.
20. ESTP  (RED L.E.D.)
This L.E.D. will indicate the status of the Emergency
Stop button. If the button is pressed in, then the
L.E.D. will be OFF.
21. FSWP  (RED L.E.D.)
This L.E.D. will indicate the status of the water
pressure switch. If the water is turned off of not
connected, providing no pressure, the L.E.D. will be
OFF.
22. SPR3  (RED L.E.D.)
This is for a spare input to be used with
programmable outputs.
23. SPR2  (RED L.E.D.)
This is for a spare input to be used with
programmable outputs.
24. SPR1  (RED L.E.D.)
This is for a spare input to be used with
programmable outputs.
25. RVLV  (RED L.E.D.)
This L.E.D. will indicate the status of the rear gas
valve. If the rear gas valve is open (ON), then the
L.E.D. is ON.
26. FVLV  (RED L.E.D.)
This L.E.D. will indicate the status of the front gas
valve. If the front gas valve is open (ON), then the
L.E.D. is ON.
27. 24IN  (RED L.E.D.)
This L.E.D. will indicate 24 VAC to the board.
28. +5V
The 24 VAC regulated to power components on the
board.
29. Mode (blinking) communication between display
and input/output (I/O) boards.