Alliance Laundry Systems UW60P2 Washer User Manual


 
Operation
F232090
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WE-6 Microcomputer
The WE-6 microcomputer control is a field-
programmable solid-state control capable of storing
and running up to 39 preprogrammed ready-to-use
cycles. A detailed description of these cycles can be
found in the Programming section of this manual
under Individual Cycle Charts. (If this machine’s
computer has been equipped with special
preprogrammed cycles, a separate insert listing these
cycles has been included in the resealable plastic bag
which contained this manual.)
Never turn the power off while the computer mode
switch is in the PROGRAM position. Such action will
disorder portions of the programmed data,
necessitating reprogramming of some or all of the
existing cycles. Always return the mode switch to
RUN position before turning the power off.Never
leave the mode switch key inserted in the switch lock
where it may be accessible to unauthorized personnel
not familiar with programming procedures.
The computer control in this washer-extractor is
continuously on the alert for problems within the
machine. When the computer detects a problem, it
immediately flashes a letter or number or both on the
display. It may activate the signal buzzer as well.
LED Display
The WE-6 microcomputer has a six-digit LED display.
References to display indications pertain to the first
four digits of the display reading left to right. The last
two digits on the right side of the display will indicate
either the last cycle used or the current cycle in
progress. See Figure 4.
The table which follows, entitled “Display
Interpretations,” lists the various displays and what
they mean.
MC007A
Figure 4
Function
Being
Executed
Step
Number
Cycle
Number