62
Table 8
TEMP SELECT
POSITION
WATER LEVEL
SWITCH
ACTION
Pump and Brake Solenoid
Agitate Function
Water Inlet System & Water Level Switch
Spin Function
HC
WC
CC
WW*
(This setting only
on 4-temperature
models)
n/a
Pump & Solenoid
Actuate
Dry Agitate
Empty
Full
Warm Fill
Agitate
Pump & Brake
Solenoid
Actuate, Spin
Empty
Full
Pump & Brake
Solenoid
Actuate
n/a
To terminate this test and return to normal operation, unplug the washer power cord from the power
outlet for more than five seconds and then plug the power cord back into the outlet.
To terminate this test and return to normal operation, unplug the washer power cord from the power
outlet for more than five seconds and then plug the power cord back into the outlet.
Table 9
STEP
3 SECOND OPERATIONS
Wash Cycle/Status LED on
Rinse Cycle/Status LED on
Spin Cycle/Status LED on
Cold Water Valve
Hot Water Valve
Motor Lead - Yellow
Motor Lead - Red
Pump and Solenoid
All OFF
Return to Step 1
1
2
3
4
5
6
7
8
9
10
Automatic Operations Test (Set TEMP SELECT: Cold/Cold - Initiate Entry Sequence)
The Automatic Operations Test checks LEDs, Valves, Solenoid, Pump and both Drive Motor Windings
by turning each component on for approximately three seconds.
Actuator and Switch Test (Set TEMP SELECT: Hot/Cold - Initiate Entry Sequence)
(Preferred Service Test)
The Actuator and Switch Test is designed to detect malfunctions in the transmission, water inlet
valves, pump, solenoid and clutch, and the lid switch. Each function is tested separately by turning the
TEMPERATURE SELECT switch as indicated in
Table 8
. Press the START/PAUSE button to start
and end each test.
Opening and closing the lid during any of the these tests will verify the lid switch.
NOTE: CYCLE SELECT setting has no effect on the Actuator and Switch Test.