Speed Queen TMB796C Washer User Manual


 
Gas Requirements
M414905
36
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Gas Supply Pipe Sizing and Looping
Figure 19
TMB2126N
1 Gas furnace (120,000 Btu/hr.) 7 Minimum Pipe Size is 0.5 in. (12.7 mm)
2 Gas water heaters (400,000 Btu/hr. each) 8 25 ft. (7.6 m)
3 Gas space heaters (70,000 Btu/hr. each) 9 Main regulator
4 Sediment traps, supply pressure taps and 10 Gas meter
shut-off valves. Refer to Figure 18. 11 Pressure regulator (if required)
5 1 in. (25.4 mm) gas pipe loop 12 50 pound tumblers (120,000 Btu/hr each)
6 19 ft. (5.8 m) 75 pound tumblers (165,000 Btu/hr each)
F75 pound tumblers (215,000 Btu/hr each)
SAMPLE CALCULATIONS:
Equivalent length = Total length of main gas supply pipe to the far end of the tumblers.
= 25 ft. + 19 ft. (7.6 m + 5.8 m) gas supply pipe
= 44 ft. (13.4 m) Total Gas Line
Total Btu/hr. = The sum of the Btu/hr. of all 50 pound tumblers being fed by the main gas supply pipe.
= 9 x 120,000
= 1,080,000 Btu/hr.
Using Table 5, the main supply pipe diameter should be 2 in. (51 mm).
IMPORTANT: Gas loop piping must be installed as illustrated to equalize gas pressure for all tumblers
connected to single gas service. Other gas using appliances should be connected upstream from loop.
123456789
M
9
12
8
6
3
2
1
10
11
7
5
4