Speed Queen TMB796C Washer User Manual


 
Installation
17
M414905
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Location Requirements
The tumbler must be installed on a level floor. Floor
covering materials such as carpeting or tile should be
removed.
To assure compliance, consult local building code
requirements. The tumbler must not be installed or
stored in area where it will be exposed to water and/or
weather.
IMPORTANT: DO NOT block the airflow at the
rear of the tumbler with laundry or other articles.
Doing so would prevent adequate air supply to the
combustion chamber of the tumbler.
A typical tumbler enclosure is shown in Figure 1. Note
the minimum and maximum dimensions. Local codes
and ordinances must be complied with.
IMPORTANT: Install tumblers with sufficient
clearance for servicing and operation, refer to
Figure 1.
Figure 1
WARNING
To reduce the risk of serious injury, install
lockable door(s) to prevent public access
to rear of tumblers.
W055
TMB2131N
NOTE: Shaded areas indicate adjacent structure.
1 0.5 in. (13 mm) recommended between machines for removal or installation
2 Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece may
be used to conceal the opening; zero clearance allowed for trim.
3 4 in. (102 mm) maximum header thickness
4 12 in. (305 mm) minimum clearance permitted for remainder
5 Guard
6 Provision for make-up air
7 24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes
8 0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed
TMB2131N
3
1
4
5
6
7
2
WARNING
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances.
W056