Conair 100 Clothes Dryer User Manual


 
Screen
Screens 15-27 require access
code 754.
SCREEN 15 (Set up Screen)
SCREEN 16 (Set up Screen)
SCREEN 17 (Set up Screen)
SCREEN 18 (Set up Screen)
SCREEN 19 (Set up Screen)
Function
Control Function Descriptions
(continued)
This is the process deviation temperature
screen. The range is 5 - 20°F (-15.0 -
-6.7°C). This is the deviation temperature
band around the set point. If the dryer
goes outside this band, the dryer will dis-
play a passive alarm (P1).
This is the process high temperature
screen. This is the high temperature limit.
If the process temperature reaches this set-
point, the dryer will shutdown on alarm
A1.
This is the process heater autotune screen.
The autotune function can be turned on by
pressing the + key. Once the + key is
pressed, the screen will show On and then
start the autotune process. This may take a
minute or so to complete. When finished,
the display will read "don". The new PID
values are automatically saved.
This is a regeneration temperature screen.
This is the regeneration heater autotune
screen. The autotune function can be
turned on by pressing the + key. Once the
+ key is pressed, the screen will show On
and then start the autotune process. This
may take a minute or so to complete.
When finished the display will read "don".
The new PID values are automatically
saved.
400
C02
C
off
C03
C
425
C04
C
10
C01
C
off
C05
C
Operation l 4-9
4
Operation
Central
When supplied for
central drying appli-
cations, these func-