Conair 100 Clothes Dryer User Manual


 
The DC-1 Dryer Control Panel
4-2 l Operation
Set Point Actual
1 Process Temp.
2 Regen. Temp.
3 Return Air Temp.
4 Auto Start
5 Load Time (MDC)
6 Activate Setback Temp.
7 Setback Temp.(Process)
8 Setback Load Rate
9 PM1 Dewpoint
Shutdown Alarms
A1 Process High Temp.
A2 Process Loop Break
A3 Process Heater High Temp.
A4 Regen. Heater High Temp.
A5 Carousel Index Too Long
A6 Carousel Index Failure
A7 Return Air High Temp.
Passive Alarms
P1 Process Temp. Deviation
P3 Regen. Temp. Deviation
P5 Return Air High Temp.
Auto Start
Desiccant Indexing
Set-Back Temp.
Process Blower
Process Pressure
Process Heater
Regen. Blower
Regen. Pressure
Regen. Heater
Start and Stop
Buttons
Press Start to start the dryer.
Press Stop to stop the dryer.
Increment/
Decrement Buttons
Used to increase or
decrease values.
Acknowledge
Alarm Button
Press once to silence the
optional audible alarm and
display alarm messages.
Press again to clear the
alarm.
Actual
Display
Shows the actual
temperature value.
Set Point
Display
Shows the set
point value.
Menu List
Numbers 1, 2, 3, and 4 are standard items that will
always be present. Numbers 5, 6, 7, 8, and 9 are
screens associated with options. If the option is not
installed the screen will not be displayed.
Alarm
Codes
See
“Troubleshooting”
Section 6 for a
more complete
listing of alarm
codes.
Scroll Button
Press to scroll
through the
closed loop menu
list. Pressing the
scroll button
moves you down
the list.
Menu
Number
Display
Displays the
menu number
corresponding to
what is shown in
the set point and
actual displays.
Can also display
letters for alarm
and setup screens.
Central
Menu List
Numbers 2, 3, and 4 are standard items that will
always be present. Number 9 is a screen associated
with an option. If the option is not installed, the
screen will not be displayed.