Conair 100 Clothes Dryer User Manual


 
Appendix l D-1
Installing the Flow Control (Optional)
You can add optional flow controls to the D Carousel Dryer for use with the
optional aftercooler or precooler. Installation is easy.
The optional flow control requires a source of city, tower, or chiller water. You can
use water at temperatures up to 85°F ( 30°C). But the water flow should be at least
1 gal/min (3.8 liters/min) for models D15, D25, D50; or 2 gal/min (7.6 liters/min)
for models D75 and D100.
1 Stop the dryer and lockout the main power.
2 Mount the flow control to the back of the dryer using the existing holes and
the four 8-16 sheet metal screws provided. The exact location for the flow
control depends on its usage and the model of the dryer (see the table below).
Usage / Dryer Model Mounting Location
(Looking at the Back of the Dryer)
Aftercooler / All models Left, top corner
Precooler / D 15, 25, and 50 Models Right, top corner
Precooler / D 75 and 100 Models Right, bottom corner