Conair 100 Clothes Dryer User Manual


 
Specifications: MDC(continued)
Central
When config-
ured as a central
dryer, the MDC
option is not
available.
SPECIFICATION NOTES:
* Consult Conair about other available hopper selections.
† SCFM stands for standard cubic feet per minute, referenced to a pre-specified pressure,temperature and relative humidity.In most cases, SCFM is referenced to
14.7 PSIA 68° F and 0% relative humidity.ACFM stands for actual cubic feet per minute, and must be supplied with a temperature reference, due to the change in
air density with temperature. Because dryers operate at a relatively low pressure the effects on air density are negligible.
When drying below 150° F a precooler is required. When drying above 250° F an aftercooler and insulated drying hose is required.
§
Dryers running at 50 HZ will have 17% less airflow,and a 17% reduction in material throughput.
** Temperatures above or below the recommended levels may affect dryer performance.Tower,chiller or municipal water sources can be used.
Throughputs will vary by type of material. Consult Conair for throughput information.
Specifications may change without notice. Check with a Conair representative for the most current information.
Dryer model MDC15 and MDC25 MDC50 MDC75 MDC100
Hopper selection* CH10-1 CH10-1.5 CH14-2 CH14-3 CH14-4 CH18-4 CH18-6 CH24-8 CH24-12 CH24-15
Performance characteristics
Air flow {SCFM}† 12 20 35 50 80
Air flow {ACFM @250° } 16 27 47 67 107
Drying temperature
All models 100° -375° F {38°-191° C} with options
Dew point All models -40° F {-40° C}
Maximum conveying distance ft {m} 8 {2.44} vertical; 6 {1.83} horizontal
with long-distance option 15 {4.57} vertical; 50 {15.24} horizontal
Dimensions inches {cm}
A - Height to top of hopper 56 {142.2} 67 {170.2} 58 {147.3} 69 {175.3} 80 {203.2} 66 {167.6} 78 {198.1} 76 {193.0} 89 {226.1} 105 {266.7}
B - Total height 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 100 {254.0} 105 {266.7}
C - Width 48 {121.9} 48 {121.9} 48 {121.9} 48 {121.9} 48 {121.9} 54 {137.2} 54 {137.2} 54 {137.2} 54 {137.2} 54 {137.2}
D - Depth 30 {76.2} 30 {76.2} 30 {76.2} 30{76.2} 30 {76.2} 36 {91.4} 36 {91.4} 36 {91.4} 36 {91.4} 36 {91.4}
Weight lb {kg}
Shipping 590 {268} 600 {272} 650 {29.5} 660 {299} 670 {304} 785 {356} 805 {365} 1025 {465} 1055 {478} 1075 {488}
Voltages§ Total amps STD LONG DIST.STDLONG DIST. STANDARD LONG DIST. STANDARD LONG DIST. STANDARD LONG DIST.
208V/3 phase/60 Hz 8.6 11 9.5 11.9 12.1 14.5 20.2 22.6 NA NA
240V/3 phase/60 Hz 7.7 10.1 8.5 10.9 10.8 13.2 17.8 20.2 27.3 29.7
400V/3 phase/50 Hz 4.3 5.4 4.7 5.8 6.2 7.3 10.3 11.4 14.8 15.9
480V/3 phase/60 Hz 3.8 4.6 4.2 5.0 5.4 6.2 8.9 9.7 12.7 13.5
575V/3 phase/60 Hz 3.1 4.5 3.4 4.8 4.4 5.8 7.3 8.7 10.4 11.8
Total kilowatts kW 2.8 3.4 3.1 3.7 4.0 4.6 6.7 7.3 9.6 10.2
Water requirements {for optional aftercooler}
Recommended temperature ** 70°-90° F {21°-32° C}
Water flow gpm {liters/min.} 3 {11.36} / 1/2 inch NPT female fittings
Appendix l G-5