Conair 100 Clothes Dryer User Manual


 
Screen
SCREEN 10 (Setback
Temperature Option)
SCREEN 11 (Setback Options)
SCREEN 12 (Setback Load Rate
Option)
Function
Control Function Descriptions
(continued)
If the dryer has the setback on temperature
option installed, this is the temperature
setpoint for the air at the outlet of the dry-
ing hopper. When this setpoint is reached,
the dryer will automatically change the
process setpoint to the setpoint shown on
Menu number 7, Screen 11. When the
temperature at the outlet of the hopper
drops below the setpoint (menu number 6)
by the value shown under C07, screen 22,
the dryer will return to the normal drying
setpoint.
If the dryer has the setback on temperature
option installed, this is the temperature set-
point to which the process air will revert
once the air at the outlet of the hopper has
reached its setpoint. (Menu number 6)
If the dryer has the optional setback on
load rate option, this screen shows the
number of load dumps per hour, setpoint
and actual. When the actual drops below
the setpoint the dryer will go into setback
mode. When the actual goes above the set-
point, the dryer will return to the normal
process temperature.
150
120
6
145
250
7
5
7
8
Operation l 4-7
4
Operation
Central
When supplied for
central drying applica-
tions, these functions
are not available.