American Dryer Corp. ML-410 Washer/Dryer User Manual


 
62
ML-410
Sprinkler Option Temperature Controller Settings
NOTE: Refer to Controllers Users Manual for further information on controller options.
Message
Display
Message
Description
Settings
SP
TEMPERATURE
SET POINT
575º F OR 301.6º C
ALHi ALARM HI 575º F OR 301.6º C
(NOTE: ADJUST SAME AS SP)
InP INPUT DEVICE P 385 = RTD
INPUT
F-C º F OR º C SELECT TYPE REQUIRED
(FAHRENHEIT OR CELSIUS)
dpt DECIMAL POINT
0,
N
O DECIMAL POINT
InPt INPUT FAULT TIMER 0.2
SPL SET POINT LOW 500
(SETTING CAN NOT BE LOWER)
SPH SET POINT HIGH 700
(SETTING CAN NOT BE HIGHER)
SPSt SET POINT STATE rE
(REVERSE ACTION)
SPOL
SET POINT OUTPUT
LOW LIMIT
0%
(NOT USED)
SPOH
SET POINT OUTPUT
HIGH LIMIT
100%
(NOT USED)
SPLP SET POINT LAMP 0 OFF
(LAMP OFF WHEN OUTPUT IS ON)
AL HIGH ALARM ONLY Hi
ALt ALARM TYPE Abs
(ABSOLUTE ALARM)
ALrE ALARM RESET OnOf
(AUTOMATIC RESET)
ALPi
ALARM POWER
INTERRUPT
OFF
(ALARM INHIBIT IS OFF)
ALiH ALARM INHIBIT OFF
(ALARM INHIBIT IS OFF)
ALSt
ALARM OUTPUT
STATE
CLOS
(CLOSES CONTACTS AT ALARM SET POINT)
ALLp ALARM LAMP
O ON
(ALARM LAMP IS ON WHEN ALARM
CONTACT IS CLOSED)
SECr SECURITY CODE
FULL SECURITY -
SET TO 110 (DISPLAYED AS 1) "VIEW ONLY"
NO SECURITY -
SET TO 111 (DISPLAYED AS 4)
"ALL FEATURES UNLOCKED"