46
I. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be preformed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.
1. Turn on electric power to the dryer.
2. Make sure the loading doors are closed and the lint drawer is closed.
3. Make sure green power button is in and illuminated.
4. Microprocessor (computer) system operational test -- to start the dryer;
a. Display will read READY.
b. Press D (preprogrammed) cycle key on the touchpad of the keyboard.
5. The dryer will then start. (i.e., Blower, tumbler [basket] and heat).
6. The L.E.D. (light emitting diode) display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.
NOTE: Press the UP ARROW to view the tumbler (basket) temperature at anytime.
NOTE: The dryer can be stopped at any time by pressing the CLEAR/STOP key. If the
temperature is above the Cool Down set point when the CLEAR/STOP is pressed, the
dryer will go into a Cool Down cycle. If the CLEAR/STOP key is pressed again at
this point the cycle that was in progress will be canceled and returned to the READY
state. If the temperature is below the Cool Down set point. The cycle that was in
progress will be canceled, and go to Wrinkle Guard.
7. When the programmed drying time has expired, the Phase 7 OPL microprocessor controller (computer)
will proceed into the Cool Down Cycle (Mode).
8. Once the COOL DOWN Cycle begins at the end of the heat cycle the L.E.D. display will read COOL
DOWN TEMP ___/___MINUTE REMAINING. At the end of the heat cycle the dryer will shut off the
heat, and continue the Fan and Tumbler until the Cool Down Time, or temperature is reached.
9. Once the COOL DOWN cycle is completed the Phase 7 OPL microprocessor controller (computer) will
proceed into the Wrinkle Guard cycle. The Audio Alert tone will sound for (the amount set in Audio Alert
ON Time). The L.E.D. display will read WRINKLE GUARD. The times are fixed at two (2) minutes
OFF, two (2) minutes ON for a max time of 99 minutes. These times are not programmable. During the
ON time, the Blower (fan) and the tumbler (basket) will start to rotate (without heat for two [2] minutes).
The Phase 7 OPL microprocessor controller (computer) will repeat this process until the Maximum Wrinkle
Guard On Time has expired (99 minutes). The L.E.D. display will then read CYCLE DONE and lockout
the dryer functions until the doors are opened. It will then return to READY.
NOTE: Mechanical functions of the dryer is not allowed during the ON time. The blower (fan)
must be OFF to perform mechanical functions. However the CLEAR/STOP key may
be pressed at anytime to end a the Wrinkle Guard cycle. Mechanical functions of the
dryer is allowed during the OFF time.