American Dryer Corp. ML-410 Washer/Dryer User Manual


 
44
5.
Steam Damper System Operation
The MLS-410 steam damper system shown in the illustration below, allows the coil to stay constantly
charged eliminating repeated expansion and contraction. When the damper is opened, the air immediately
passes through the already hot coil, providing instant heat to start the drying process. When the damper is
closed, ambient air is drawn directly into the tumbler (basket), allowing a rapid cool down.
Diagram 1 shows the damper in the heating (open) mode, allowing heat into the tumbler (basket/drum).
Diagram 2 shows the damper in the cool down (closed) mode, pulling ambient air directly into the tumbler
(basket/drum) without passing through the coils.
NOTE: With the dryer off or with no air supply, the steam damper is in the cool down mode as
shown in Diagram 2.