American Dryer Corp. ML-410 Washer/Dryer User Manual


 
43
4.
Steam Damper Air System Connections
The MLS-410 is manufactured with a pneumatic (piston) damper system which requires an external supply
of compressed air. The connection is made at the left hand side on top of the dryer.
a. Air Requirements
b. Air Connections
Air connection to system --- 1/8-inch N.P.T.
c. No air regulation is provided with a standard ML-410 dryer. External regulation of 80 PSI (5.512 bars)
must be provided. It is suggested that a filter/regulator assembly (with gauge) be added to the compressed
air line just before the dryer connection. This is necessary to insure that correct and clean air pressure
is achieved. The filter/regulator assembly (with gauge) is provided on dryers with the AUTOMATIC
DOOR, TILTING, or SPRINKLER CIRCUIT OPTION.
ylppuSriAdesserpmoCerusserPriA
lamroNISP08
srab15.5
ylppuSmuminiMISP07srab28.4
ylppuSmumixaMISP09srab02.6
stnelaviuqecirtemnidetatserasaeradedahS