American Dryer Corp. ML-410 Washer/Dryer User Manual


 
35
2.
Electrical Service Specifications
IMPORTANT: THE DRYER MUST BE CONNECTED TO THE ELECTRIC SUPPLY
SHOWN ON THE DATA LABEL THAT IS AFFIXED TO THE REAR OF
THE RIGHT HAND ELECTRICAL ENCLOSURE.
WARNING: 208 VAC and 230 VAC ARE NOT THE SAME. Any damage done to the dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
M LG-410 (Gas)
M LS-410 (Steam)
25 HP (ADC Part No. 181006) Blower Motor
7-1/2 HP (ADC Part No. 181017) Drive
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC
AND
230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE
: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
Dual Element
Time Delay
CIRCUIT
BREAKER
208 3/4 81 #3 100 110
230 3 78 #3 100 110
380 3/4 49 #6 60 90
416 3/4 44 #6 60 90
460/480 3/4 40 #8 60 80