Alliance Laundry Systems HF25VNV Washer User Manual


 
F232072 27
Programming
1. Press the Up key until the computer display
shows the segment to be edited. Press the Start
key.
2. Use the Up or Down key to select the desired
segment time. Set this value to zero to skip the
segment. Press the Start key.
Note: The computer does not count down the
remaining cycle time during fills, drains, cool-
down, or prior to first achieving the programmed
heat temperature when heating. The computer
resumes counting down cycle time once the
programmed fill level is reached, when the machine
has drained, and after a programmed heat
temperature is reached.
3. If the temperature-controlled fill SETUP option
is enabled, the display will show “tFIL.” Press
the Start key.
4. Use the Up or Down key to select the desired
fill temperature. See the following table for fill
options.
If the temperature-controlled fill SETUP option
is enabled and a target temperature is set, the
selected fill valve(s) will energize for the first 3
seconds of the segment fill. The computer will
then begin operating the fill valves in an attempt
to reach the target temperature. Press the Start
key.
Note: If “AFIL” is selected and the temperature-
controlled fill SETUP option is set to “tFIL,” the
temperature for the segment must be set to zero.
5. Use the Up or Down key to select the desired
fill level. See the table below.
6. Press the Start key.
Fill Temperature Options
Display Fill Type
CFIL Cold fill
HFIL Hot fill
bFIL Warm fill
AFIL Auxiliary fill*
*This is available only if the “SUP5”/“AFIL” SETUP
option is set to “AFIL.”
Water Level Options
Display Fill Level
LO Low Level
Med Medium Level
HI High Level