F232072 19
Operation
If the computer does not receive a signal that water
level has been attained within 30 minutes, it will
alternately flash “STOP” and “FILL” and sound the
on-board beeper for ten seconds. It will then initiate
the stop routine.
Wash
As soon as water level is reached (and any
programmed temperature is reached), the displayed
time begins counting down at one-second intervals.
Agitation is active during this portion of the
segment. There are four different agitation actions
available. See the following table for more
information.
If the segment contains a heat step, the machine
begins heating after the water has reached the
programmed level.
Note: If the water does not reach the programmed
temperature in 40 minutes, the computer progresses
to the wash step.
Drain
If the cycle program segment calls for a drain, the
drain valve will open after the programmed segment
time has elapsed. If a spin step follows a drain step,
the cylinder will turn counterclockwise (forward) at
wash speed while in the drain step.
If the cycle program segment does not call for a
drain, the computer moves to the next segment of
the cycle program. If the segment is at the end of a
cycle program, the computer goes into the stop
routine.
If the cycle program segment does not call for a
spin, the cylinder will continue to agitate
throughout the drain step. When the drain has
completed, the computer moves to the next segment
of the cycle program. If the segment is at the end of
a cycle program, the computer goes into the stop
routine.
Note: The machine should drain in 30 seconds. If
the machine fails to drain, contact a qualified
service technician.
Agitation Action Options
Display Description Percentage
Ag 1
27 seconds forward,
3 seconds pause,
27 seconds reverse,
3 seconds pause
90%
Ag 2
10 seconds forward,
20 seconds pause,
10 seconds reverse,
20 seconds pause
33%
Ag 3
3 seconds forward,
27 seconds pause,
3 seconds reverse,
27 seconds pause
10%
Ag 4
4 seconds forward,
56 seconds pause,
4 seconds reverse,
56 seconds pause
6.7%