F232072 9
Safety
Always disconnect power and water supplies before
a service technician performs any service
procedure. Where applicable, steam and/or
compressed air supplies should also be
disconnected before service is performed.
AC Inverter Drive
Machines equipped with the AC inverter drive
require special attention with regard to the
operating environment.
An especially dusty or linty environment will
require more frequent cleaning of the AC
inverter drive cooling fan filter and of the AC
inverter drive itself.
Power line fluctuations from sources such as
uninterruptible power supplies (UPS) can
adversely affect machines equipped with the AC
inverter drive. Proper suppression devices
should be utilized on the incoming power to the
machine to avoid problems.
A clean power supply free from voltage spikes
and surges is absolutely essential for machines
equipped with the AC inverter drive. Nonlinear
inconsistencies (peaks and valleys) in the power
supply can cause the AC inverter drive to
generate nuisance errors.
If voltage is above 230V for 200V installations
or above 440V for 400V installations, a
buckboost transformer is recommended. If
voltage is above 240 or 480, a buckboost
transformer is required.
Sufficient space to perform service procedures
and routine preventive maintenance is especially
important for machines equipped with the AC
inverter drive.
Misuse
Never use this machine for any purpose other than
washing fabric.
Never wash petroleum-soaked rags in the
machine. This could result in an explosion.
Never wash machine parts or automotive parts
in the machine. This could result in serious
damage to the basket.
Never allow children to play on or around this
machine. Death or serious injury can result if
children become trapped in the machine. Do not
leave children unattended while the machine
door is open. These cautions apply to animals
as well.
Ensure that a ground wire from a proven earth
ground is connected to the ground lug near the
input power block on this machine. Without
proper grounding, personal injury from electric
shock could occur and machine malfunctions
may be evident.
WARNING