Alliance Laundry Systems HF25VNV Washer User Manual


 
Programming
24 F232072
Setup Mode (Continued)
To enter SETUP mode, press the Stop key while the
display is showing the temperature in the sump.
Once in SETUP mode, use the Up or Down key to
change the selected option. Use the Start key to
accept the selected option and move on to the next
one. Press the Stop key to exit SETUP mode.
Degrees Displayed in Fahrenheit or Celsius
This SETUP option affects the programming and
display of all temperatures. If “FAr” is selected, all
temperatures will display in Fahrenheit. If “CEL” is
selected, all temperatures will display in Celsius.
Acceptable ranges for programmable temperatures
are 75°F – 200°F or 25°C – 93°C.
Auxiliary Heat
Heat is a dedicated output of the V-computer, which
controls an optional heat source. If “nOHt” is
selected, the heat output will never energize during
a cycle (except briefly in the test cycle to ensure that
the output functions properly), regardless of
programmed temperature settings. If “HEAt” is
selected, the output will energize during a cycle if
the three following conditions are true:
A nonzero heat temperatureis programmed.
The computer senses that the present
temperature is below the programmed target
temperature.
There is at least a low water level in the
machine.
Note: Do not enable the auxiliary heat SETUP
option and disable the temperature-controlled fill
option on machines not equipped with auxiliary
heat. The machine will pause for 40 minutes during
any cycle segment where the fill water temperature
does not equal or exceed the programmed value of
the heat step.
Supply 5 or Auxiliary Fill
If “SUP5” is selected, the output labeled AF on the
solid state output board can be used to control a
fifth supply signal. This SETUP option must be
selected to program a “SUP5” or a “SUP6” (supply
1 and supply 5 combined) in a cycle step.
If “AFIL” is selected, the output labeled AF can be
used to control an auxiliary fill valve. Auxiliary fills
can be programmed to low, medium, or high water
level. It is also possible to program an overflow
(flush) in Prewash. This SETUP option must be
selected to program an “AFIL” in a cycle step.
Temperature-Controlled Fill
If “tFIL” is selected, a temperature-controlled fill
can be programmed for any segment. This SETUP
option must be selected to program a “tFIL” in a
cycle step. If “ntFL” is selected, this feature is
disabled.