Alliance Laundry Systems HF25VNV Washer User Manual


 
Operation
16 F232072
Display Indications
Display Meaning Display Meaning
FP1 Program identification code (ROM). This is an
example only.
Med Medium water level
Hold Wait...power has just been turned on. HI High water level
CY Cycle (followed by two-digit number) SUP1 Supply 1
tESt/CYC* Test cycle selected. SUP2 Supply 2
FAr Degrees Fahrenheit SUP3 Supply 3
CEL Degrees Celsius SUP4 Supply 4
Heat Auxiliary heat enabled. SUP5 Supply 5 (SETUP option)
noHt Auxiliary heat disabled. SUP6 Supply 6 (supply 1 and 5)
tFIL Temperature-controlled fill enabled. SUP7 Supply 7 (supply 3 and 4)
ntFL Temperature-controlled fill disabled. SLo/For Gentle wash speed, forward direction
CooL Automatic cool-down enabled. SLo/rEv Gentle wash speed, reverse direction
noCL Automatic cool-down disabled. norM/For Normal wash speed, forward direction
Ag 1 Agitation 1 selected (90% agitation). norM/rEv Normal wash speed, reverse direction
Ag 2 Agitation 2 selected (33% agitation). drAI Drain enabled.
Ag 3 Agitation 3 selected (10% agitation). nodr Drain disabled.
Ag 4 Agitation 4 selected (6.7% agitation). dISt Distribution (load balancing before extract)
AgSn Agitation speed normal
SPIn/tIME*
Reads “SPIn” for one second, then “tIME”
followed by time for spin.
AgSL Agitation speed low
PMP Pump output enabled (future use only). SPn1 Lowest of three spins
nPMP Pump output disabled (future use only). SPn2 Middle of three spins
PrE Prewash segment (1st of 11 segments) SPn3 Highest of three spins
UASH Wash segment (2nd of 11 segments) STOP Stop routine
FIL1 First fill (3rd of 11 segments) SdLY Spin coast delay
FIL2 Second fill (4th of 11 segments) donE Cycle and stop routine have ended.
FIL3 Third fill (5th of 11 segments) dFLt Drive fault detected.
FIL4 Fourth fill (6th of 11 segments) door Door not properly closed.
FIL5 Fifth fill (7th of 11 segments)
bAL/FAIL*
Balancing routine failed during test cycle after
10 attempts to balance load.
FIL6 Sixth fill (8th of 11 segments)
FIL7 Seventh fill (9th of 11 segments)
FILL/STOP*
Programmed water level not reached after 30
minutes.
FIL8 Eighth fill (10th of 11 segments)
FIL9 Ninth fill (11 of 11 segments)
FULL
The computer detects low water level or higher
when none should be present.
CFIL Cold fill
bFIL Warm fill (both hot and cold)
rotA
Computer detects possible rotation of motor
when there should be none.
HFIL Hot fill
AFIL Auxiliary fill (SETUP option)
tSFL
Temperature sensor failure or temperature out of
range.
Lo Low water level
*Display indications separated by a slash represent a flashing display.