ADC ML-82 Clothes Dryer User Manual


 
21
To Replace Burner Tubes
1. Refer to “Replace Gas Valve” and follow Steps
#1 through Step #6.
2. Remove four (4) screws securing the Hot Surface
Ignitor (HSI) module mounting bracket.
3. Remove front flanges of the burner tubes to the
burner tube rest.
4. Remove the screws securing the burner tube rest
to the oven and remove this rest.
5. Remove screws securing burner box cover plate
to the oven and remove the cover.
6. Remove burner tubes by sliding them out.
7. Replace by reversing procedure.
To Replace HSI Module
1. Discontinue electrical power to the dryer.
2. Remove the wires connected to the terminal strip
at the bottom of the module. (Mark correct
location of each wire to aid in replacement on
new module).
3. Remove the four (4) pal nuts securing the module
to the mounting bracket.
4. Replace module by reversing procedure.
5. Reestablish electrical power to dryer.
C. TO REPLACE BURNER HI-LIMIT THERMOSTAT (GAS MODELS ONLY)
1. This thermostat is an important safety device as an added
protection against failure of the airflow (sail switch) to open
in the event of motor failure or reduced airflow conditions.
IMPORTANT: Under no circumstances should heat
circuit safety devices ever be disabled.
NOTE: Models manufactured as of 1998 are equipped
with a manual reset hi-limit thermostat.