6 - 8
Indication
C:00
C:01
C:02
C:03
C:04
C:05
C:06
C:07
C:08
Control Action
Door is Locked
Filling by cold water inlet valve
Distribution system is set to Prewash position
Fill by hot water inlet valve
Basket rotates clockwise at wash speed
Heater is switched ON.
Basket rotates clockwise with wash speed.
If there is not enough water in the tub, the
water inlet valve will be switched ON to fill-in
the minimum water quantity.
NOTE: On GHW 9100 Models only the
Temperature Sensor will be checked
Drain Pump is ON
Basket rotates counterclockwise
from 35 to 90 rpm
within 15 seconds
Basket rotates counterclockwise
with max. speed
Basket speed > 1100 rpm
Actuators to be Checked
Door Lock System
Flowmeter, Cold water inlet valve
Dispenser motor,
Dispenser contact
Hot water inlet valve
Motor, MCU control
Heater, Temperature Sensor
Drain Pump
Motor, MCU control
Motor, MCU control
DIAGNOSTIC TEST
The control must be in the OFF state before pressing the touch-pad sequence to start the test.
Starting the test mode
Close the door.
Press the Control On button.
Select the DRAIN/SPIN cycle.
Select NO SPIN by pressing the SPIN SELECT button, as needed.
Push Prewash Option button four (4) times within five (5) seconds. C:00 will show in the display.
NOTE: If Model does not have PREWASH Mode as an option, press RINSE/HOLD.
If the Starting procedure fails, push PAUSE/CANCEL button. Then repeat the starting sequence.
Test Program Control during Execution
To advance to the next step of the test procedure, push Prewash Option button two (2) times.
Overview Test Program