Whirlpool GHW9200L Washer User Manual


 
4 - 7
Fig. 4-24
ACCESSING THE
MOTOR CONTROL UNIT
Access to the Motor Control Unit may require
removing the left front shock absorber.
Separate the taped flap of the top of the MCU to
the cabinet.
Using a flat bladed screwdriver, lift up on the
plastic tab under the front right corner of the
motor controller box.
(Fig. 4-26 - INSET)
Fig. 4-26
INSET
Slide the box forward to
release the two tabs at
the back of the box from
the bottom panel of the
washer.
(Fig. 4-27)
Fig. 4-27
REMOVING THE SHOCK ABSORBERS
The tub is held in position by four shock absorb-
ers, two in front
(Fig. 4-25)
and two at the back.
Each shock absorber can be disconnected from
the tub by turning the top of the shock mount
counter clockwise, 90°. The shock can be re-
moved from the washer by turning the bottom
shock mount counterclockwise, 90°.
Front
Shock
Absorbers
Fig. 4-25
Rear Shock
Absorbers
Open the door on the control box to access to
the test points of the Motor Control Unit.
(Fig. 4-
28)
Fig. 4-28
Place Blade
of
Screwdriver
Here
To clean out the large item filter, turn the large
knob counterclockwise and pull it out.
(Fig. 4-24)
NOTE: It is recommended that a small pan be
placed under the pump prior to removing the large
item filter. There will be water in the pump hous-
ing.