WARNI NG
!
To avoid risk of electrical shock, personal injury or death,
disconnect power to unit before servicing.
Disassembly Procedures
22 16026502 ©2005 Maytag Services
Motor Removal
1. Disconnect power supply to unit.
2. Lift Top Cover, see “Top Cover Removal” procedure.
3. Remove Front Panel, see “Front Panel Removal”
procedure.
4. Remove Motor ground wire.
5. Remove Motor Shield.
6. Remove Motor wire harness connector.
7. Remove three screws retaining Motor to Base.
Flume/Thermistor Removal
1. Disconnect power supply to unit.
2. Remove Console, see “Console Disassembly”
procedure.
3. Remove Flume screw from top of Top Cover.
4. Lift Top Cover, see “Top Cover Removal” procedure.
5. Remove two Flume retaining screws from bottom of
Top Cover.
6. Remove hose clamp and Flume/Diverter Hose.