Disassembly Procedures
20 16026502 ©2005 Maytag Services
Top Cover Removal
1. Disconnect power supply to unit.
2. Insert a plastic putty knife between the Top Cover and
Front Panel. Press the locking clip to release the Top
Cover. Repeat for both sides. Support lid with free
hand and rotate top until it comes to rest on hinge
stop.
Hinge/Lid Removal
1. Disconnect power supply to unit.
2. Lift Top Cover, see “Top Cover Removal” procedure.
3. Remove Hinge screw on each side.
4. Remove Hinge from Pivot Post.
5. Remove Lid Switch Striker by removing screw from the
Lid side.
Lid Switch Removal
1. Disconnect power supply to unit.
2. Lift Top Cover, see “Top Cover Removal” procedure.
3. Remove two screws retaining Lid Switch.
4. Remove Lid Switch from housing.