Refrigeraon Updates
KitchenAid & Whirlpool Measured Fill Calibraon Procedure
French Door/Double Door and SxS Models:
GSS30C6EY*0, GSS30C7EY*0
KFXS25RY**0, KSF26C4XY**0, KSC23C8EY**0,
KSC23C9EY**0, KSC24C8EY**0, KSO24C8EY**0, KSF26C6XY**0, KSF26C7XY**0
Code Date: HR109 to HR135 (March 2011)
Concern: The Smart Valve currently used in the refrigerator models listed is being phased out
and replaced by a new ow washer that uses a med ll process.
Soluon: It may be necessary to adjust the ll to compensate for low water pressure.
A calibraon video is available on Service Maers:
RefrigFieldCalibraonforMeasuredFillDispenser.wmv
Service Pointers that also address this Issue:
W10405575 and W10405576
To Calibrate:
Press SW1 and SW2 simultaneously for 3 seconds.
Release both buons when you hear the CHIME indicator.
The display will show 01 to indicate the control is in step 1 of the diagnoscs roune.
Toggle SW4 or SW5 to advance to Step 49.
Note: When you stop on a step, the step number will quickly illuminate and
the step value connually ashes.
Enter a measured ll of 8 OZ. Fill a measuring cup.
If the volume is more or less than the selected amount, calibraon is needed.
Note: The default seng for step 49 is either 31 ml/sec ( 1.05 oz/sec) or
35 ml/sec (1.2 oz/sec).
This value can be changed in whole number increments of 1 ml/sec
(.03 oz).
To calibrate the measured ll feature, this value needs to match the
actual ow rate of the product.
Connued on next page.