Disconnect & measure white 3-pin
connector (with blue wires) to
measure door latch motor. Measure
between pins 1-2 (pin 1 at far left).
Motor should read ~ 211 - 259 Ω.
Disconnect & measure white 2-pin
connector (with black wires) to
measure NTC. NTC should read:
• 20ºC (68ºF): 5.4 - 6.5 kΩ
• 30ºC (86ºF): 3.5 - 4.3 kΩ
• 40ºC (104ºF): 2.3 - 2.9 kΩ
Disconnect & measure blue 2-pin
connector (with blue wires) to
measure drain pump. Pump should
read ~ 80 - 94 Ω.
Disconnect & measure white 6-pin connector (with blue wires) to
measure drum drive motor. Motor should read (pin 1 is at far right):
• Pins 1-2: 14 - 35 Ω
• Pins 3-4: 1.5 - 10 Ω
• Pins 5-6: 0.7 - 2.1 Ω