Bosch Appliances WFR2460UC Washer User Manual


 
WFR 2460 Service Tips
WFR 2460 Service Tips
--
--
Configuring
Configuring
Replacement Control Modules
Replacement Control Modules
43
NOTE: Note original equipment washer modules are
factory configured and CANNOT
be changed in the field.
42010011 T5: Variant
Max. spin speed
2! 1000 RPM
3! 1100 RPM
4! 1200 RPM
5! 1300 RPM
6! 1400 RPM
7! 1500 RPM
8! 1600 RPM
Language
0! German
1! English
2! French
3! Dutch
4! Italian
5! Spanish
E! Polish
Replacement WFR 2460 control modules
(# 484014) aren’t configured. Please
follow these instructions to configure
replacement modules.
Water inlet
0!
Without Aqua
stop, cold water
1! With Aqua stop,
cold water
2! Without Aqua
stop, hot water
Push Menu button to select 1st #
for max. spin speed (until 1st #
flashes), then push Select button
until “4” (for 1200 RPM max.) is
chosen. Push Start/Pause button
to save setting.
Push Menu button to select 2nd #
for water inlet (until 2nd #
flashes), then push Select button
until “2” (hot water) is chosen.
Push Start/Pause button to save
setting.
Push Menu button to select 7th #
for language (until 7th # flashes),
then push Select button until “1”
(for English) is chosen. Push
Start/Pause button to save setting.
After installing module, enter test program by first
pushing and holding Menu & Select buttons, then
rotating selector switch (dial) ccw to Permanent
Press Cold (until display comes on).
Push Menu button repeatedly to scroll to test “T5”:
Model Variant Coding. Red light on Start/Pause
button will be flashing. Push Start/Pause button to
enter test T5 to change #’s (red light will stop
flashing when test T5 has been entered).
Push Menu button to scroll to each # (when desired
# is flashing). For each #
, push Select button until
correct setting is chosen, then push Start/Pause
button to save setting. Repeat until settings for all
eight #’s are saved -- U.S. washers must
show
42010011.
When settings for all eight #’s are saved, exit test
program by rotating selector switch (dial) cw to Off.
NOTE: See test program page 61
for all test T5 settings.
42010011 T5: Variant
42010011 T5: Variant
Sample Displays
1st Edition/Revision 5 (1/20/04)