Alliance Laundry Systems Washer-Extractor Washer User Manual


 
Installation
F232135
52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 32
4. Connect hoses to nozzles by pushing each hose
over nozzle lip. Hoses should fit snugly onto
nozzles and then secured with proper clamps.
NOTE: Do not attempt to make chemical injection
supply pump electrical connections to points other
than those provided specifically for that purpose by
the factory.
Machines connected to 200VAC provide L1 and L2
fused outputs rated at 3 amps which may be used to
power 208 – 240VAC supply pumps.
Machines connected to 400VAC do not provide L1 and
L2 outputs. An external power source must be
provided to power the chemical supply pump.
Do not use L1 or L2 with the common line to deliver
120VAC to chemical injection supply pumps if the
machine is equipped with a control transformer.
Consult the supply vendor instructions for operational
details about supply injections.
125 Pound OPL Models
(With Optional Dispenser)
Refer to Figure 33 and Figure 34.
1. Remove plugs from base. Plugs are assembled
inside tubing ring.
2. Install strain reliefs included in seal nut.
3. Insert tubes through base. Do not remove dry
supply cups. Tube should extend into plastic cup,
with exception of softener tube, which should be
routed to outside of cup.
4. Tighten seal nut to prevent tubing from escaping
assembly.
U149M
Nozzles:
1 Detergent
2 Bleach
3 Sour
4 Soft
5 Speciality
U149M
1
2
5
3 AND 4
Dangerous Voltages. Will cause damage
to the machine and microprocessor. Do
not attempt to obtain 110VAC by using L1
or L2 with the common. Do not use a
240VAC power wire in the washer-
extractor and an earth ground to obtain
110VAC.
W365
CAUTION