Installation
47
F232135
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Specifications
50 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
2 Speed Models
C 380 – 415 50 3 4 6 15 14 2.5 39 50 6 16
D220 – 2405033122012 4 6470 4 25
E220 – 2405012153010 6 3740 8 10
F 440 – 480 60 3 3 6 15 14 2.5 39 50 6 16
J 200 50 3 3 10 20 12 3 x 4 N/A
O208 – 2406033102012 4 6470 4 25
Y*208 – 2406012153010 6 3740 8 10
Variable-Speed Models
N 440 – 480 50/60 3 3 4 15 14 2.5 41.6 45 8 10
P 380 – 415 50/60 3 3 4 15 14 2.5 36.5 40 8 10
Q 200 – 240 50/60 3 3 6.3 15 14 2.5 62.6 70 4 25
T 200 – 240 50/60 1 2 6.3 15 14 2.5 N/A
X 200 – 240 50/60 1 or 3 2 or 3 6.3/6.3 15 14 2x2.5
3x2.5
N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
*Coin models only.
Tabl e 13