Alliance Laundry Systems Washer-Extractor Washer User Manual


 
Installation
F232135
50
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
If machine fails to operate after power is connected,
proceed as follows:
1. Disconnect power.
2. Unlock and raise top cover.
3. Check circuit fuse.
For mechanical timer, P-computer and
S-computer models, control circuit fuse is located
on center brace.
For EDC and V-computer models, dual control
circuit fuses (one primary, one secondary) are in
control module. A decal identifies fuse(s) and
provides fuse-rating appropriate to that specific
model.
For NetMaster models, circuit fuses are located
on side of control box.
For A-control and B-control models, circuit fuses
are located on the output board.
4. If control circuit fuse has blown, replace with
fuse of appropriate rating as identified by decal.
IMPORTANT: Call a qualified electrician if
replacement fuse blows.
Steam Requirements
(Steam Heat Option Only)
For machines equipped with optional steam heat,
install piping in accordance with approved commercial
steam practices. Steam requirements are shown in
Table 17.
IMPORTANT: Failure to install the customer
supplied steam filter may void the warranty.
Steam Supply Information
Steam inlet
connection size
18 – 80 pound 1/2
in. (13 mm)
125 pound 3/4
in. (19 mm)
Number of steam inlets 1
Recommended pressure 30 – 80 psi
(2.0 – 5.4 bar)
Maximum pressure 80 psi
(5.4 bar)
Table 17
Hot Surfaces. Will cause severe burns.
Turn steam off and allow steam pipes,
connections and components to cool
before touching.
W505