Alliance Laundry Systems HX Washer User Manual


 
9001900 69
Section 4 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
Disconnect electrical power to the washer-extractor before servicing it.
Close the gas shut-off valve to the washer-extractor (when applicable) before servicing it.
Never start the washer-extractor with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W461R1
WARNING
22. KEYMODE SWITCH REMOVAL AND
INSTALLATION
Refer to Figure 6.
REMOVAL
a. Turn off power to the machine.
b. Remove the top cover. Refer to Paragraph 19.
c. Disconnect the wires from the keymode switch.
d. Using a 5 mm nut driver, remove the nuts that
attach the keymode switch to the control panel.
e. Separate the keymode switch from the
keymode base and remove them.
INSTALLATION
a. Position the keymode base and keymode switch
and connect them.
b. Using a 5 mm nut driver, replace the nuts that
attach the keymode switch to the control panel.
c. Reconnect the wires to the keymode switch.
d. Replace the top cover. Refer to Paragraph 19.
e. Turn on power to the machine.
Figure 6
CFD11S
Keymode
Base
Keymode
Switch
Control
Panel