Alliance Laundry Systems HX Washer User Manual


 
38 9001900
Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
8. NO OUTPUT VOLTAGE TO COMPONENTS
Figure 1
Component Voltage Reading Points Voltage Reading
Water
Flush A Clear wire to Blue wire 220 Volts AC
Hard Fill White/Black wire to Blue wire 220 Volts AC
Hot Fill Red wire to Blue wire 220 Volts AC
Cold Fill Gray wire to Blue wire 220 Volts AC
Flush C White wire to Blue wire 220 Volts AC
Flush B Purple wire to Blue wire 220 Volts AC
Drain
Drain Motor Fan Clear wire to Blue wire 220 Volts AC
Drive Fan Clear wire to Blue wire 220 Volts AC
Door
Door Latch Switch Orange/White wire to White/Brown wire 5 Volts DC
Door Lock Switch Orange/White wire to White/Black wire 5 Volts DC
Door Solenoid Black wire to Red or White wire 70 Volts AC
Tilt
Tilt White/Purple wire to White/Orange wire 5 Volts DC
Soap
S4 White/Orange wire to Black wire 24 Volts DC
S5 Red/Black wire to Black wire 24 Volts DC
S6 Yellow/Red wire to Black wire 24 Volts DC
S7 White/Brown wire to Black wire 24 Volts DC
S8 Red/Gray wire to Black wire 24 Volts DC
S9 White/Red wire to Black wire 24 Volts DC
Component Voltage/Reading Points Chart
CFD2000S
Figure 1
1
Is there
voltage (refer to
Figure 1) on the main
board terminals that
the wires going to the
component are
connected
to?
2
Replace the
main board.
NO
Repair/replace the wiring as
needed.
YES
NO
Is
there
voltage (refer to
Figure 1) on the
wires on the input
side of the
components?
Repair/replace the component
as needed.
YES