Alliance Laundry Systems HX Washer User Manual


 
9001900 67
Section 4 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Cycle 39 — Test Program
Step Description Min:sec Step Definition Corrective Action
1 Cold Fill to
High Level
0:30 The machine should fill with cold water to
high level within 30 seconds and, when it
does, a buzzer will sound.
Refer to the “Machine Did Not Fill Alarm
Analysis” flowchart.
2 Drain 1 0:10 The machine should drain within 10 seconds
and, when it does, a buzzer will sound.
Refer to the “Empty Alarm Analysis
flowchart.
3 Hot Fill to Low
Level
5:00 The machine should fill with hot water to low
level within 5 minutes and, when it does, a
buzzer will sound.
Refer to the “Machine Did Not Fill Alarm
Analysis” flowchart.
4 Auxiliary Fill
to Medium
Level
5:00 The machine should fill with water to
medium level within 5 minutes and, when it
does, a buzzer will sound.
Refer to the “Machine Did Not Fill Alarm
Analysis” flowchart.
5 Heat (150°F) 1h00 This step is needed only if the machine is
equipped with auxiliary heat (e.g., steam or
electric heating). If the temperature isn’t
reached within the time programmed, an
alarm will sound.
Check the components used for the
auxiliary heating (e.g., steam valve or
heating elements).
6 Cold Fill to
High Level
0:30 The machine should fill with cold water to
high level within 30 seconds and, when it
does, a buzzer will sound.
Refer to the “Machine Did Not Fill Alarm
Analysis” flowchart.
7 Supply 1 0:30 Supply compartment A should flush for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
8 Supply 2 0:30 Supply compartment B should flush for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
9 Supply 3 0:30 Supply compartment C should flush for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
10 Supply 4 0:30 Supply relay 1 should be activated for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
11 Supply 5 0:30 Supply relay 2 should be activated for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
12 Supply 6 0:30 Supply relay 3 should be activated for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
13 Supply 7 0:30 Supply relay 4 should be activated for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
14 Supply 8 0:30 Supply relay 5 should be activated for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
15 Supply 9 0:30 Supply relay 6 should be activated for 30
seconds.
Refer to the “No Fill Analysis” flowchart.
16 Wash 2 3/27
(80°F)
0:30 The basket should rotate forward 3 seconds,
pause for 27 seconds, rotate in reverse for 3
seconds, pause for 27 seconds, etc.
Refer to the “No Motor Operation (With or
With No AC Drive Fault” flowchart.
17 Wash 3, no
agitation (80°F)
0:30 The basket should not rotate for 30 seconds. If the basket does rotate, check the
program.
18 Wash 4 10/3
(80°F)
0:30 The basket should rotate forward 10 seconds,
pause for 3 seconds, rotate in reverse for 10
seconds, pause for 3 seconds, etc.
Refer to the “No Motor Operation (With or
With No AC Drive Fault” flowchart.
19 Wash 1, no
reverse (80°F)
0:30 The basket should rotate forward for 30
seconds without pausing.
Refer to the “No Motor Operation (With or
With No AC Drive Fault” flowchart.
20 Drain 1 1:00 The machine should drain within 1 minute
and, when it does, a buzzer will sound.
Refer to the “Empty Alarm Analysis
flowchart.
Table 1