Alliance Laundry Systems D355IE1B Washer/Dryer User Manual


 
28
504524
Multi-dryer Installation
Exhaust Requirements . . .
The illustration below shows a typical example of a
multiple dryer installation. Note how each dryer has its
own exhaust system vented to the central exhaust duct.
IMPORTANT: Static pressure in each dryers
exhaust duct should be no greater than that shown in
the chart on Page 28. This can be measured with a
manometer placed on the exhaust duct approximately
two feet (61 cm) from the dryer. See Page 28. All
dryers connected to the main collector duct should be
in operation when pressure is checked.
Installing an exhaust system does not eliminate the
necessity of cleaning the dryer lint filter before each load.
The dryer interior and the complete exhaust system
should be cleaned periodically by a qualified service
person to remove any lint build-up.
IMPORTANT: DO NOT block the airflow at the
bottom of the dryers front panel with laundry, rugs,
etc. Blockage will decrease airflow through the dryer,
thus reducing the efficiency of the dryer.
(continued))
D359IE2A
58786
BACKDRAFT
DAMPER
(Available
through
your local
authorized
parts source)
CLEAN-OUT
COVER
MUST BE
PROVIDED
WEATHER HOOD
OR SWEEP ELBOW
(No cap or screen)
To reduce the risk of electric shock,
disconnect the electrical service to the dryer
before cleaning.
W043
WARNING