Location Requirements . . .
Select a location with a solid floor.
No other fuel burning appliance should be installed in the
same closet with the dryer unit.
The dryer unit must not be installed or stored in an area
where it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer unit
with a 1/4" driver. All four legs must rest firmly on the
floor so the weight of the dryer is evenly distributed. The
dryer unit must not rock.
IMPORTANT: Unless completely assembled, DO
NOT slide the dryer unit across the floor. DO NOT
slide the unit once the leveling legs have been
extended, as the legs and the base could become
damaged.
The dryer unit needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown below.)
NOTE: Shaded areas
indicate adjacent structure.
AA
D358IE2A
B
C
E
E
D
Dryer And Exhaust Duct Clearances
Area Description
Minimum
Clearance
A Dryer Sides 0" (0 cm)
B Dryer Top (Rear 24") 2" (5.1 cm)
C Dryer Rear 4" (10.2 cm)
D Dryer Top (Front 4") 0" (0 cm)
E Exhaust Duct from Combustible Construction 2" (5.1 cm)