STEP 4: (ELECTRIC DRYER ONLY)
Connect Electrical Plug
For further assistance, refer to Section on Electrical
Requirements.
IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply cord
kit rated 240 Volts (minimum) 30 Amperes and
labeled as suitable for use in a clothes dryer.
NOTE: For more detailed information on connecting
three-wire or four-wire plugs, refer to Section on
Electrical Plug Connection.
NOTE: Four-wire cord is required for mobile homes
or where codes do not permit grounding through
neutral.
STRAIN
RELIEF
NUT
TYPICAL
THREE-WIRE
RECEPTACLE
POWER CORD
(Three-Wire)
STRAIN
RELIEF
D275IE0D
Three Wire
Three Wire
NUT
TYPICAL
FOUR-WIRE
RECEPTACLE
POWER CORD
(Four-Wire)
STRAIN
RELIEF
D006IE0A
STRAIN
RELIEF
Four Wire
D276IE1A
CENTER
WIRE
(NEUTRAL)
STRAIN
RELIEF
(NOT SUPPLIED
WITH DRYER)
NEUTRAL
TERMINAL
GROUND
WIRE
"L2"
TERMINAL
"L1"
TERMINAL
GROUND
SCREW
GROUND
TO NEUTRAL
WIRE
Three-Wire Connection
D171IE1A
WHITE
WIRE
(NEUTRAL)
GROUND
SCREW
NEUTRAL
TERMINAL
"L1"
TERMINAL
BLACK
WIRE
GROUND
WIRE
STRAIN
RELIEF
(NOT SUPPLIED
WITH DRYER)
GROUND
WIRE
"L2"
TERMINAL
RED
WIRE
Four-Wire Connection
NOTE: Dryer is shown with access cover removed for illustration purposes only. NEVER operate dryer with