Miele G 7883 Washer User Manual


 
4. Restoring the factory
settings
^
Turn the program selector to "STOP"
f .
^
Turn the machine off.
^
Press and hold "Display" ß and
"Start" 6. At the same time, turn the
lab washer on with the "On/Off"
button.
The displays shows the current
program status "P...".
The "Fill/Drain" indicator lights.
^ Press and hold "Drying" 0 until "E33"
appears in the display.
^ Turn the program selector to any
position (except "STOP").
The display shows either "00" or "PP".
"00" = factory setting; electronic was
not reprogrammed.
"PP" = electronic was reprogrammed.
^ If "PP" is displayed press "Display" ß
to change from "PP" to "00".
^
Press the "Start" 6 button. "SP"
appears in the display.
^
Press the "Start" 6 button again.
All factory settings are now restored.
If the hardness level setting in the
water softener had been changed,
this will reset to the factory setting of
340 ppm (19 gr/gal). This will need
to be reset to suit the hardness level
in your area.
Changes in programs "Custom",
"Inorganica" and "Organica" cannot
be reset.
Programming special functions