Miele G 7883 Washer User Manual


 
3. Setting the buzzer
A buzzer can be set to signal the
following:
End of program = continuous buzzer
Error = rhythmic buzz
Timer to allow sampling of the last
final rinse water
= intervals of 3 short buzzes and
2 seconds break
^
Turn the program selector to "STOP"
f.
^
Turn the machine off.
^ Press and hold "Display" ß and
"Start" 6. At the same time, turn the
lab washer on with the "On/Off"
button.
The displays shows the current
program status "P...".
The "Fill/Drain" indicator lights.
^ Press "Drying" 0 4 times. "E04"
appears in the display.
^
Turn the program selector to
"Inorganica". A number between "20"
and "27" appears in the display.
"20" = Buzzer is turned off
"21" = End of program
(factory setting)
"22" = Error
"23" = Error and End of program
"24" = Test sample extraction
"25" = End of program and
Test sample extraction
"26" = Error and Test sample
extraction
"27" = All functions
(End of program, Error,
Test sample extraction).
^ Press and hold "Display" ß until the
desired value appears in the display.
^ Press the "Start" 6 button. "SP"
appears in the display.
^ Press the "Start" 6 button again. The
change has been saved.
^ Please note the changed setting:
To turn the buzzer off:
^
Turn the program selector to "STOP"
f or press the "Display" ß button.
Programming special functions