Maytag DV316LG Clothes Dryer User Manual


 
6-2
No Problem What To Do
1
Will Not Start or Run
• All wires are hooked up to their corresponding terminals.
• Dryer is plugged in.
• Blown fuse or circuit breaker.
• Door switch functional...door closed. Check for error code 3 (See Table for code
de nition).
• Start/Pause rotary selector dial functional.
• Control Board operational.
• Belt off or broken and Belt Cut-off Switch operates.
• Drive motor functional.
• Check motor winding resistance: 2.88ohms between pin #3 and 4, 3.5ohms
between pin #4 and 5.
2 Motor runs/ tumbler will not turn
• Belt off or broken/damaged.
• Idler tension spring too weak or stretched.
• Idler pulley jammed or stuck.
3
Runs a few minutes and then
stops
• Lint buildup around drive motor.
• Low voltage present.
• Blower impeller blocked in blower housing.
• Drive motor - start switch contacts stuck closed.
4
Blows fuses or trips circuit
breaker
- Is the belt connected well?
- Is the winding of the motor continuous?
(Rotor winding, stator winding, generator)
- Is the motor protector normal?
• If above points are not found, the PCB assembly is out of order.
Replace it.
5
Blows fuses or trips circuit
breaker
(Gas Model)
• During ignition the dryer will draw X amps. With the burner ON, the dryer will
draw X amps. If the dryer is drawing amperages above this, then the house
wiring, fuse box or circuit breaker is suspected to be at fault.
• Igniter harness loose and shorted to base.
• Incorrect wiring or wire shorted to ground.
• Drive motor winding shorting to ground.
6 Will not heat (motor runs)
Open heating element.
• Hi-Limit trips easily or is open.
• Regulating thermostat trips easily or is open.
• Membrane switch open.
• Check Thermistor.
7
Will Not Dry Gas Model
Poor Gas Ignition
When the dryer is operated on a heat setting, the igniter should be energized and
burner shall re within 45 seconds at 120 VAC. The failure of a component in this
system will usually be indicated by one of three symptoms:
8 The igniter does not glow
If the igniter does not heat up, remove power and using an ohmmeter, check the
following:
• Open ame sensor
• Open igniter
• Shorted booster coil
• Open wiring
• Bad motor switch ( Neutral supply)
• No power from control ( L1 supply)
9 Igniter glows - No gas ignition
If the igniter heats up but the main burner ame is not ignited, remove power and
using an ohmmeter, check the following:
• Open secondary coil
• Open holding coil
• Open wire harness
• Stuck ame sensor (Stuck closed)
10
The gas is ignited but the ame
goes out
If a normal ignition takes place and after a short while the ame goes out, check
for the following:
• Radiant sensor contacts opening prematurely.
• Weak gas valve coil may open when stressed by higher Temps.
• Weak Hi-Limit
• Poor venting
• Bad drum seals
11
Improper drying
clothes wrinkled
Rough texture
long dry time
• Lint lter is not clean.
• Restriction in exhaust.
• Outside exhaust hood damper door stuck closed.
• Exhaust too long, too many elbows, ex ductwork installed.
• Poor intake air available for the dryer.
• Incorrect tumbler speed. Tumbler belt slipping.
• Blower impeller bound; check for foreign material in blower area.
• Customer overloading dryer.
• Check clothing labels for fabric content and cycle selected.
• Clothes too wet due to insuf cient spin out by washer.
12 Noisy and/Or Vibration
• Thumping Check for loose tumbler baf e, rear tumbler roller(s) worn or
misaligned, out-of-round tumbler or high weld seam on tumbler.
• Ticking Check for loose wire harness or object caught in blower wheel area.
• Scraping Check for front or rear bulkhead felt seal out of position or worn
tumbler front bearings.
• Roaring Check for blower wheel rubbing on blower housing or bad motor
bearings.