99
1
2a 2b
5 4
K21
K22
6
3
1 2
5
4
3
Y51
3
4
6665A
6666
3
4
Function (machines built for mop washing)
Electricheatingwithoutfusiblecut-outon
element
The three heating elements in the machine are
connected to separate phases and switched on
andoffusingtwoserialheatingcontactors.Hea-
tingcontactorK21iscontrolledbyprogramme
unitA1,output(x36:7).HeatingcontactorK22is
regulated by a standalone mechanical level con-
trol.Inorderforbothcontactorstobeactivated,
the level in the machine must have been appro-
ved by both the level control in programme unit
A1andthemechanicallevelcontrol.
Thewaterlevelinthemachinemustbe90scale
unitsormoreinorderforthemechanicallevel
control to be activated.
Theprogrammeunitreceivesinformationonthe
water temperature in the machine through an
analoguesignalfromthetemperaturesensor
situated in the outer drum. The programme unit
controls the heating contactors to achieve the
setwatertemperatureforthecurrentwashing
programme.
The mechanical level control prevents the ele-
mentfromactivatingiftheprogrammeunitor-
dersheatdespitethefactthatthereisnowater
in the drum.
Steamheating
The steam valve is controlled by the programme
unitA1,output(X336:7).
Heating
1. Heatingelements
2a. ProgrammeunitA1
2b. Interlocksignal
3. Supplyvoltage
4. Temperaturesensor
5. I/OBoard
6. Levelcontrol
1. Steamvalve
2. ProgrammeunitA1
3. Rearcontrolunit
4. Temperaturesensor
5. I/O-card