60
A
B
1
2
3
4
1
2
3
4
5
7
6
9
12
6598
13
6572
External connections to I/O module type 2
Connectionofexternaldosingequipment
The external dosing equipment power
supply must never be connected to the
machine’s incoming terminal block or to
the edge connectors on the IO-board.
Machinesttedwithconnectors
• Connectthepumpassemblytoconnections
AandBonthewashingmachine.Connect
thesignalcabletoBandthepowersupplyto
A.
Machineswithoutconnectors
• Connecttheexternalpumpassemblyfor
liquidwashingdetergenttoI/Omodule2,
whichislocatedtotherightoftheincoming
power supply.
TheI/Omodulehasedgeconnectorsforcon-
nectingexternalpumps.
Theedgeconnectorsmayberemovedfrom
the board when connecting the cabling.
1=N
2=L
4=Earth
11=N
18=Program
12=Signal1
13=Signal2
14=Signal3
15=Signal4
16=Signal5
12
13
I/O modules