Electrolux W4180N/S Washer User Manual


 
137
Troubleshooting
Error code 60, ACTUATOR CIRCUIT
The DLCU processor controls the door lock actuator coil. The DLCU pro-
cessor checks continuously that the coil is engaged. DLCU can detect a
break in the circuit (>50 kohm) (DLCU cannot detect a short in the circuit).
If there is a break in the actuator circuit, CPU will be notified; the error
message will disappear if the error ceases.
CPU reads the error message when the program starts and finishes and
generates an error code, the error message is ignored between these two
occasions.
Reason:
• Theerrorcanbecausedbyabreakinthecablesbetweenthehatch
lock and the CPU, or caused by a error in the hatch lock solenoid.
• ErrororbreakintheCPUcircuits.
Action:
• Iftheerrorreturnsafterareset,andisnotcausedbyaerrorinthe
hatch lock or the cables for the hatch lock, change the CPU.