American Dryer Corp. ML-460 Clothes Dryer User Manual


 
14 American Dryer Corp. 113068-7
2. Electric
a. Basket (Tumbler) Motors
The disconnects for the one (1) basket (tumbler) motor is located in the lower heat console. The left
drum (basket [tumbler]) motor disconnect is located in the base of the lower heat console to the right.
On the cable the mechanical connection should be made to the respective junction box. Remove the
two (2) screws that hold down the cover to each junction box. Insert cable end in the junction box and
fasten with lock nut. Then, begin to connect the four (4) wires with the same color tape identifiers
together with the four (4) wires already in the junction box. Make these connections with wire nuts and
PVC electrical tape. Replace the cover and the two (2) cover screws that hold down the cover to the
junction box.
b. Temperature Probe, Base, and Basket (Tumbler) Disconnects
The disconnects are located in the lower heat console. The temperature probe disconnect is located on
the upper shelf towards the left. The base disconnect and the basket (tumbler) disconnect are located
on the base towards the right. Check identifying tapes to ensure proper assignments of connectors to
the proper base. Check for proper keying and connect disconnect to the proper base. Engage hold
downs on base and verify that the clamps are properly locked.