73
K. Microprocessor controller (computer) L.E.D. (light emitting diode) display reads “door” and
the microprocessor controller (computer) “DOOR” L.E.D. indicator is on...
1. Failed microprocessor controller (computer).
L. Microprocessor controller (computer) will not accept any keyboard (touchpad) entries, (i.e.,
L.E.D. display reads “FILL” and when keyboard [touchpad] entries are selected, the L.E.D.
display continues to read “FILL”)...
1. Dryer is not in level position.
2. Broken connection between level switches.
3. Level switches need to be adjusted.
4. Failed keyboard (touchpad) label assembly.
5. Failed microprocessor controller (computer).
6. Dryer has a “Heater Fault.”
7. Selector switch is not in “Dry” position.
M. Microprocessor controller (computer) will only accept certain keyboard (touchpad) entries...
1. Failed keyboard (touchpad) label assembly.
2. Failed microprocessor controller (computer).
N. Microprocessor controller (computer) locks up and L.E.D. display reads erroneous message(s)
or only partial segments...
1. Transient power voltage spikes...disconnect the electrical power to the dryer, wait one (1) minute and reestablish
power to the dryer. If problem is evident ...
a. Failed microprocessor controller (computer).
b. Failed keyboard (touchpad) label assembly.
O. Dryer stops during a cycle, microprocessor controller (computer) buzzer (tone) sounds for
5-seconds, L.E.D. display reads “dSFL” for approximately 30-seconds and then returns to
“FILL”...
1. Loose connection somewhere between the microprocessor controller (computer) and the microprocessor
temperature sensor.