American Dryer Corp. AD-410 Clothes Dryer User Manual


 
72
H. Both drive motor and blower (impellor/fan) motor are not operating...microprocessor
controller (computer) L.E.D. (light emitting diode) motor indicator dots and the “door” L.E.D.
indicator are on but the relay output L.E.D. indicators are off (microprocessor controller
[computer] L.E.D. display does not read “door”).
1. Failed microprocessor controller (computer).
I Microprocessor controller (computer) L.E.D. display reads “dSFL” continuously and the
buzzer (tone) sounds every 30-seconds...
1. Fault in microprocessor heating sensing circuit ...
a. Failed microprocessor temperature sensor.
b. Blown “dSFL” 1/8-amp fuse on the microprocessor controller (computer).
c. Failed microprocessor controller (computer).
d. Broken wire or connection between the microprocessor controller (computer) and the microprocessor
temperature sensor.
J. Microprocessor controller (computer) L.E.D. display reads “door” and the microprocessor
controller (computer) “DOOR” L.E.D. indicator is off...
1. Fault (open circuit) in main door/lint drawer switch circuit ...
a. Lint drawer is not closed ALL the way.
b. Lint drawer switch is out of proper adjustment.
c. Failed lint drawer switch.
d. One (1) of the main door switches has failed.
e. One (1) of the main door switch contact magnets is either missing or is broken.
f. Failed door switch relay.
g. Broken wire/connection in main door or lint drawer switch circuit.
h. Drive motor and/or blower (impellor/fan) motor thermal overload reset has tripped.
2. Failed 24 VAC step down transformer.
3. Master control relay (MCR) is not engaged.
4. Blown 24 VAC control circuit fuse (fuse 3 [F3]).