4. Steam Damper Air System Connections
The ADS-410 is manufactured with a pneumatic (piston) damper system which requires an external supply
of compressed air. The connection is made at the left hand side on top of the dryer.
a. Air Requirements
b. Air Connections
Air connection to system --- 1/8” N.P.T.
c. No air regulation is provided with a standard AD-410 dryer. External regulation of 80 PSI (5.51 bars)
must be provided. It is suggested that a filter/regulator assembly (with gauge) be added to the compressed
air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is
achieved. The filter/regulator assembly (with gauge) is provided on dryers with the AUTOMATIC
DOOR OPTION or THE SPRINKLER CIRCUIT OPTION.
Compressed Air Supply Air Pressure
Normal 80 PSI 5.51 bars
Minimum Supply 70 PSI 4.82 bars
Maximum Supply 90 PSI 6.20 bars
Shaded areas are stated in metric equivalents